== Initial Setup Notes == Below is the commands used to configure the switches we purchased in 2021. The switches are installed as follows:

|| || '''Rack 1''' || '''Rack 2''' || '''Liebert''' ||'''Rack 4''' ||'''Rack 5''' ||
|| 01 || !R1S1:S58050-48T4Q (241) || !R2S1:S5860-20SQ (240) || || !R4S1:S5800-48T4S (247)|| !R5S1:S5810-48TS-P (248)||
|| 02 || !R1S2:S58000-48T4S (242) || !R2S2:S5800-48T4S (243) || || || ||
|| 03 || || !R2S3:S5800-48T4S (244) || || || ||
|| 04 || || !R2S4:S5800-48T4S (245) || || || ||
|| 04 || || !R2S5:S5800-48T4S (246) || || || ||

||<-13>!R2S1:S5860-20SQ, 10.10.129.240 ||
||!R1S2||!R2S2||!R2S3||!R2S4 ||!R2S5 ||!R4S1 ||!R5S1 || || || || || ||!R1S1||
||INET1||INET2|| || || || || || || || || || || ||


== Initial Setup Notes for 5800 Series Switches ==
Line 8: Line 22:
Line 11: Line 24:
Switch(config)# username <username> privilege 4 password <password>
Line 12: Line 26:
Switch(config-line)# login
Switch(config-line)# line-password abc
Switch(config-line)# login local
Switch(config-line)# exit
Line 15: Line 29:
}}} }}}   
Line 26: Line 40:
== Interface == '''Configure Management IP'''
{{{
Switch# configure terminal
Switch(config)# management ip address 10.10.129.X/24
Switch(config)# exit
Switch# show management ip address
}}}
Line 28: Line 48:
The // at the end of the line indicates the start of a comment: '''Create VLANs'''
{{{
Switch# configure terminal
Switch (config)# vlan database
Switch (config-vlan)# vlan 10 name Server
Switch (config-vlan)# vlan 100 name Office
Switch (config-vlan)# vlan 116 name Labs
Switch (config-vlan)# vlan 119 name Firewalled
Switch (config-vlan)# exit
Switch (config)# end
Switch#
}}}
Line 30: Line 61:
{{{
Switch# show interface status //show status of all the ports
Switch# show interface eth-0-49 //shows the status of eth-0-49
}}}
'''Setup Management VLAN Interface'''
Line 44: Line 72:
== Backup and Restore the switch Configuration == '''Set the banner to show the name of the switch'''
{{{
Switch# configure terminalThe // at the end of the line indicates the start of a comment:
Switch# banner login # You are logged into RXSY #
Switch# exit
Switch# show running //validates that it worked
}}}

'''In the web interface'''

 * Configuration
   * Ethernet Status (Change eth-0-50 to trunk)
   * VLAN (Set VLANs for 10,100,116,119 as appropriate - default is 116; Make sure to change eth-0-50 default 10 allow 10,100,116,119)

 * Maintenance
   * System Configuration (file out page and save)
   * User Management (Add scot and vadmin; change password for admin)
   * Reboot/Save (save the configuration)

 * Network
   * IP Routing
     * IPv4 Static Route Information
       * New:
       * Destination = 0.0.0.0
       * Mask = 0.0.0.0
       * Nexthop = 10.10.129.1
       * Distance = 1

== Common Commands ==

The // at the end of the line indicates the start of a comment:

===Show Port Status===

{{{
Switch# show interface status //show status of all the ports
Switch# show interface eth-0-49 //shows the status of eth-0-49
}}}


===Show VLAN information for port===
{{{
switch# show interface switchport interface eth-0-1
}}}

=== Backup and Restore the switch Configuration ===
Line 57: Line 130:

=== LACP configuration on S5850 10 GIG Switch ===

{{{
Switch# configure terminal
Switch(config)# port-channel 1 load-balance-mode dynamic
Switch(config)# interface eth-0-47
Switch(config-if)# no shutdown
Switch(config-if)# channel-group 1 mode active //active is the key word to get you LACP!
Switch(config-if)# edit
Switch(config)# [repeat previous 4 for each port]
Switch(config)# end
Switch# show channel-group summary
}}}

fs.com Switches purchased in 2021

Below is the commands used to configure the switches we purchased in 2021. The switches are installed as follows:

Rack 1

Rack 2

Liebert

Rack 4

Rack 5

01

R1S1:S58050-48T4Q (241)

R2S1:S5860-20SQ (240)

R4S1:S5800-48T4S (247)

R5S1:S5810-48TS-P (248)

02

R1S2:S58000-48T4S (242)

R2S2:S5800-48T4S (243)

03

R2S3:S5800-48T4S (244)

04

R2S4:S5800-48T4S (245)

04

R2S5:S5800-48T4S (246)

R2S1:S5860-20SQ, 10.10.129.240

R1S2

R2S2

R2S3

R2S4

R2S5

R4S1

R5S1

R1S1

INET1

INET2

Initial Setup Notes for 5800 Series Switches

SSH into the switch with the default user:pass = "admin:admin"

First Change the password, note that we are using local authentication mode, not "aaa" mode. What is aaa mode? That's for authenticating against a radius/TACACS+ server.

Switch# configure terminal
Switch(config)# username  <username> privilege 4 password <password>
Switch(config)# line vty 0 7
Switch(config-line)# login local
Switch(config-line)# exit
Switch(config)# exit

Set the time

Switch# configure terminal
Switch(config)# clock set datetime 11:30:00 10 26 2013
Switch(config)# clock set summer-time dst date 3 13 2022 02:00:00 11 6 2022 02:00:00 120
Switch(config)# exit

Configure Management IP

Switch# configure terminal
Switch(config)# management ip address 10.10.129.X/24
Switch(config)# exit
Switch# show management ip address

Create VLANs

Switch# configure terminal
Switch (config)# vlan database
Switch (config-vlan)# vlan 10 name Server
Switch (config-vlan)# vlan 100 name Office
Switch (config-vlan)# vlan 116 name Labs
Switch (config-vlan)# vlan 119 name Firewalled
Switch (config-vlan)# exit
Switch (config)# end
Switch# 

Setup Management VLAN Interface

Setup management on a vlan interface

switch# configure terminal
switch(config)# interface vlan 10
switch(config)# ip address 10.10.129.X/24
switch(config)# Ctrl+z
Switch# show management ip address

Set the banner to show the name of the switch

Switch# configure terminalThe // at the end of the line indicates the start of a comment:
Switch# banner login # You are logged into RXSY #
Switch# exit
Switch# show running //validates that it worked

In the web interface

  • Configuration
    • Ethernet Status (Change eth-0-50 to trunk)
    • VLAN (Set VLANs for 10,100,116,119 as appropriate - default is 116; Make sure to change eth-0-50 default 10 allow 10,100,116,119)
  • Maintenance
    • System Configuration (file out page and save)
    • User Management (Add scot and vadmin; change password for admin)
    • Reboot/Save (save the configuration)
  • Network
    • IP Routing
      • IPv4 Static Route Information
        • New:
        • Destination = 0.0.0.0
        • Mask = 0.0.0.0
        • Nexthop = 10.10.129.1
        • Distance = 1

Common Commands

The // at the end of the line indicates the start of a comment:

===Show Port Status===

Switch# show interface status //show status of all the ports
Switch# show interface eth-0-49 //shows the status of eth-0-49

===Show VLAN information for port===

switch# show interface switchport interface eth-0-1

Backup and Restore the switch Configuration

To backup the configuration, ssh into the switch and perform the following:

Switch# copy flash:/startup-config.conf mgmt-if scp://10.10.129.X/startup-config.conf

To download a configuration file:

Switch# copy mgmt-if scp://10.10.10.163/startup-config.conf flash:/startup-config.conf

LACP configuration on S5850 10 GIG Switch

Switch# configure terminal
Switch(config)# port-channel 1 load-balance-mode dynamic
Switch(config)# interface eth-0-47
Switch(config-if)# no shutdown
Switch(config-if)# channel-group 1 mode active //active is the key word to get you LACP!
Switch(config-if)# edit
Switch(config)# [repeat previous 4 for each port]
Switch(config)# end
Switch# show channel-group summary