fs.com Switches purchased in 2021
Below is the commands used to configure the switches we purchased in 2021. The switches are installed as follows:
|
Rack 1 (Back) |
Rack 2 |
Liebert |
Rack 4 (Back) |
Rack 5 (Back) |
01 |
R1S1:S58050-48T4Q (241) |
R2S1:S5860-20SQ (240)-Back |
|
R4S1:S5800-48T4S (247) |
R5S1:S5810-48TS-P (248) |
02 |
R1S2:S58000-48T4S (242) |
R2S2:S5800-48T4S (243)-Back |
|
|
|
03 |
|
R2S3:S5800-48T4S (244)-Front |
|
|
|
04 |
|
R2S4:S5800-48T4S (245)-Front |
|
|
|
04 |
|
R2S5:S5800-48T4S (246)-Front |
|
|
|
Firewall Ports |
|
R2S2:4 U-Server VLAN |
R2S2:11 T-Firewalled |
R2S2:3 U-Public |
R2S2: 10 T-13,14,100,116 |
R2S1:S5860-20SQ, 10.10.129.240 |
||||||||||||
R1S2 |
R2S2 |
R2S3 |
R2S4 |
R2S5 |
R4S1 |
R5S1 |
|
|
|
|
|
R1S1 |
INET1 |
INET2 |
|
|
|
|
|
|
|
|
|
|
|
R2S2:5800, 10.10.129.243 |
|||||||||||||||||||||||||
1/2 |
3/4 |
5/6 |
7/8 |
9/10 |
11/12 |
13/14 |
15/16 |
17/18 |
19/20 |
21/22 |
23/24 |
25/26 |
27/28 |
29/30 |
31/32 |
33/34 |
35/36 |
37/38 |
39/40 |
41/42 |
43/44 |
45/46 |
47/48 |
49/50 |
51/52 |
10 |
20 |
116 |
20 |
Agg4-LACP |
1d,119 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
10 |
10 |
1 |
Agg4-LACP |
1d,13,14,100,116 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- Agg4: 10d,14,116,119
Contents
Initial Setup Notes for 5800 Series Switches
SSH into the switch with the default user:pass = "admin:admin"
First Change the password, note that we are using local authentication mode, not "aaa" mode. What is aaa mode? That's for authenticating against a radius/TACACS+ server.
Switch# configure terminal Switch(config)# username <username> privilege 4 password <password> Switch(config)# line vty 0 7 Switch(config-line)# login local Switch(config-line)# exit Switch(config)# exit
Set the time
Switch# configure terminal Switch(config)# clock set datetime 11:30:00 10 26 2013 Switch(config)# clock set summer-time dst date 3 13 2022 02:00:00 11 6 2022 02:00:00 120 Switch(config)# exit
Configure Management IP
Switch# configure terminal Switch(config)# management ip address 10.10.129.X/24 Switch(config)# exit Switch# show management ip address
Create VLANs
Switch# configure terminal Switch (config)# vlan database Switch (config-vlan)# vlan 10 name Server Switch (config-vlan)# vlan 100 name Office Switch (config-vlan)# vlan 116 name Labs Switch (config-vlan)# vlan 119 name Firewalled Switch (config-vlan)# exit Switch (config)# end Switch#
Setup Management VLAN Interface
Setup management on a vlan interface
switch# configure terminal switch(config)# interface vlan 10 switch(config)# ip address 10.10.129.X/24 switch(config)# Ctrl+z Switch# show management ip address
Set the banner to show the name of the switch
Switch# configure terminalThe // at the end of the line indicates the start of a comment: Switch# banner login # You are logged into RXSY # Switch# exit Switch# show running //validates that it worked
In the web interface
- Configuration
- Ethernet Status (Change eth-0-50 to trunk)
- VLAN (Set VLANs for 10,100,116,119 as appropriate - default is 116; Make sure to change eth-0-50 default 10 allow 10,100,116,119)
- Maintenance
- System Configuration (file out page and save)
- User Management (Add scot and vadmin; change password for admin)
- Reboot/Save (save the configuration)
- Network
- IP Routing
- IPv4 Static Route Information
- New:
- Destination = 0.0.0.0
- Mask = 0.0.0.0
- Nexthop = 10.10.129.1
- Distance = 1
- IPv4 Static Route Information
- IP Routing
Common Commands and Quirks
The // at the end of the line indicates the start of a comment:
Show Port Status
Switch# show interface status //show status of all the ports Switch# show interface eth-0-49 //shows the status of eth-0-49
Show VLAN information for port
switch# show interface switchport interface eth-0-1
Backup and Restore the switch Configuration
To backup the configuration, ssh into the switch and perform the following:
Switch# copy flash:/startup-config.conf mgmt-if scp://10.10.129.X/startup-config.conf
To download a configuration file:
Switch# copy mgmt-if scp://10.10.10.163/startup-config.conf flash:/startup-config.conf
LACP configuration on S5850 10 GIG Switch
Switch# configure terminal Switch(config)# port-channel 1 load-balance-mode dynamic Switch(config)# interface eth-0-47 Switch(config-if)# no shutdown Switch(config-if)# channel-group 1 mode active //active is the key word to get you LACP! Switch(config-if)# exit Switch(config)# [repeat previous 4 for each port] Switch(config)# end Switch# show channel-group summary
The final configuration was this:
R2S2: Aggregator Name Mode Protocol Ports Purpose -----------------+---------+--------------+-----------------------------------------------------------+----------- agg1(SU) DLB LACP eth-0-47(B) eth-0-48(B) (Promise 64) agg2(SD) SLB LACP(Dynamic) eth-0-45(s) eth-0-46(s) eth-0-47(s) eth-0-48(s) (Promise 32) agg4(SU) SLB LACP(Dynamic) eth-0-8(B) eth-0-9(B) (Firewall)
Where agg2 is for Promise 32 and agg4 is for Promise 64. Note if load-balance-mode doesn't work, try LACP mode.
Trunk Quirk
IF you have something acting as a tagged port, then you cannot assign it as the default VLAN.
Scenario: I have the firewall using tagged VLANs on the procurve: 13,14,100,116 All tagged - no default untagged VLAN assigned.
On the new switch, you cannot pick one of these to be the default VLAN, even though it was in the list of permitted (tagged) VLANs, it would not work. Choosing 1 (an unused VLAN) to be the default VLAN allowed it to start working again. Picky! Picky!